MPDx SED (Suni SED)
Published 2022-10-10
Subject to changes and corrections.
Version 5.0 (Build 25) (Released 2008-06-25)
- Updated sensor resolutions.
Version 5.0 (Build 20) (Released 2007-01-24)
Version 5.0 (Build 18) (Released 2006-06-23)
- Made a small change in image processing in order to ignore a small border around the image when determining the optimal brightness/contrast around an image.
- Maintenance build.
Version 5.0 (Build 16) (Released 2005-06-08)
Version 5.0 (Build 14) (Released 2004-12-13)
- Changes made to handle power problems with the 1800 that could result in a software crash.
Version 5.0 (Build 11) (Released 2004-02-17)
- Internal changes made to hardware handling.
Version 5.0 (Build 8) (Released 2004-02-09)
- Changes made to be sure that detection of other Suni hardware is not falsely interpreted as Suni digital x-ray hardware.
Version 5.0 (Build 6) (Released 2004-02-04)
- Additional DICOM information support added. Please note that you will need to additionally update the DICOM.DLL and main application before the additional DICOM information will be available.
Version 5.0 (Build 3) (Released 2004-01-12)
- Separate smoothing factors for standard and binned images.
- Image return type defaulted to standard.
Version 5.0 (Build 2) (Released 2003-12-31)
- Support for additional hardware types.
- Support for automatic firmware selection.
- SED options updated.
- Password protection removed on some of the option pages.
Version 4.0 (Build 26) (Released 2003-12-15)
- Correction made to correct multiple image capture problems..
Version 4.0 (Build 25) (Released 2003-12-10)
- Maintenance release: Window’s font is now used for various controls in the interface; extended character sets now available for a wider range of supported languages; new more efficient versions of interface controls added.
- Internal firmware handling changes.
Version 4.0 (Build 23) (Released 2003-07-08)
- Made correction to binned flaw correction to correct for floor binning function.
Version 4.0 (Build 22) (Released 2003-06-17)
- Changed flaw corrections on systems utilizing binning firmware.
Version 4.0 (Build 21) (Released 2003-05-16)
- Added ability to add sensor configurations from drives and locations other than a floppy diskette.
Version 4.0 (Build 19) (Released 2003-03-11)
- Added additional support for handling when more than 3 firmware releases are available at the same time.
Version 4.0 (Build 18) (Released 2002-12-13)
- Made power handling corrections based on the selected firmware.
Version 4.0 (Build 17) (Released 2002-12-12)
- Changed the “low power checking” option to default to enabled.
- Changed the image width used when capturing from BINNED firmware.
- Added previous firmware option for original Suni hardware.
Version 4.0 (Build 16) (Released 2002-12-10)
- Added default support for Suni’s new firmware filenames.
Version 4.0 (Build 16) (Released 2002-12-08)
- Added support for a wider range of firmware.
Version 4.0 (Build 14) (Released 2002-09-29)
- Added a default image calibration option.
Version 4.0 (Build 11) (Released 2002-05-15)
- New options added to the MPDx options.
- Changes made to support new Suni Firmware and new hardware models.
Version 4.0 (Build 6) (Released 2002-04-23)
- Added better support for selecting different types of firmware.
- Added support for the USB-1600 model of the Suni hardware.
Version 4.0 (Build 4) (Released 2002-03-28)
- Changed the default B/C and gamma settings for freshly installed systems.
Version 4.0 (Build 3) (Released 2001-03-14)
- Additional flush time options added to adjust the amount of time required to prepare sensor captures
Version 4.0 (Build 2) (Released 2001-03-03)
- Added thorough median filter
Version 4.0 (Build 1) (Released 2001-02-07)
- Modified to conform to new XVa3 3.5 specs
Version 3.0 (Build 15) (Released 2000-05-28)
- Additional improvements to image processing, handling and options.
- Automatic orientation corrected on teeth numbers 5, 21, 21 and 28.
Version 3.0 (Build 14) (Released 2000-05-02)
- Large improvements to image processing and handling.
Version 3.0 (Build 11) (Released 2000-04-16)
- Additional B/C user specified application support
- Improved support for handling errors after x-ray exposure
- Support for preventing white burnout in image
Version 3.0 (Build 9) (Released 2000-03-19)
- Image reorientation support added
- MPDx image calibration improved
Version 3.0 (Build 8) (Released 2000-02-13)
- Change made to “Processing …” display to accommodate lag on some systems
Version 3.0 (Build 7) (Released 2000-01-01)
- Confirmation message added when a new sensor is added
- “Processing” message displayed immediately after x-ray is triggered
- Fix: “User canceled” message displayed when board times out
- Raw sensor image import remembers last settings
- Fix: Blank error message returned when user cancels various functions
- New features added to report the current sensor port
- Fix: MCS file not automatically being found until entering options
Version 3.0 (Build 6) (Released 2099-12-20)
- Compiled to conform to new application interface standard
Version 2.0 (Build 14) (Released 2099-11-11)
- Battery/External power setting added to options
- “Don’t display this message again” functionality
- When background capture times out on a battery powered system, background capturing is suspended so that the battery can recharge
- Development dialog that is displayed while in background capture was removed
- Automatic selection of a sensor the first time the software is run
- Background capture and battery powered unit warnings added.